CHAPTER 13 RS-485 COMMUNICATIONS
a) Hardware CONT signal (CONT1 - 5)
Data 4bytes
0
0
b) Hardware OUT signal (OUT1 - 3)
Data 4bytes
0
0
00h
00h
00h
0 CONT5 CONT4 CONT3 CONT2 CONT1
00h
00h
00h
0
0
0 OUT3 OUT2 OUT1
(2) Control mode, Sequence mode, Alarm at present, Alarm history
Each piece of data in the control mode, sequence mode, alarm at present, and alarm history is the
code data of 1 byte.
DATA
4bytes
00h
00h
00h
Code
The content of the code varies depending on the data. For the detail, refer to the corresponding
tables below.
Control mode
Code
00h
01h
02h
Control mode
Position control
Speed control
Torque control
Alarms at present and alarm histories
Sequence mode
Code
Sequence mode
00h
Servo off
01h Servo on
02h
Zero speed stop
03h
Manual feed (JOG)
04h
Pulse operation
05h OT
06h OT
07h
In LV (under voltage)
08h
Positioning
09h
Homing
0Ah Interrupt positioning