CHAPTER 13 RS-485 COMMUNICATIONS
[Table 13-3] Assigned parameter list ○ Supported X: Not supported
Assigned
FC:17H
Data type
parameter
No.
Name
Read Write
Communication
79
Communication CONT
○
○
CONT/OUT
signal
signals
39
Communication OUT
○
×
signal
Monitor
00
Feedback speed
○
×
01
Command speed
○
×
02
Command torque
○
×
03
Peak current
○
×
04
Motor current
○
×
05
Effective torque
○
×
06
Feedback position
○
×
07
Command position
○
×
08
Position deviation
○
×
09
Command pulse
○
×
frequency
10
Feedback cumulative
○
×
pulses
11
Cumulative input pulses
○
×
12
LS-Z pulse
○
×
13
Load inertia ratio
○
×
14
DC link voltage (max.)
○
×
15
DC link voltage (min.)
○
×
16
VREF input voltage
○
×
17
TREF input voltage
○
×
18
OL thermal value
○
×
19
Regenerative resistor
○
×
thermal value
20
Power (W)
○
×
21
Motor temperature
○
×
22
Overshoot unit
○
×
amount
23
Settling time
○
×
24
Resonance frequency 1
○
×
FC:03H FC:10H
(Read) (Write)
○
○
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
Modbus RTU Communications 13-19
13