CHAPTER 13 RS-485 COMMUNICATIONS
13
Data type
Data name
Address
(hex.)
Applicable
FC
03h 10h
Format
(with a sign)
Setting range
(default value)
Positioning status
+ M code
5200
Positioning
  status: Refer to (No) M code: 0-FFh (FFh)
[Table 5-5].
Data Stop timer
1
Stop position
Rotation speed
5201
5202
5203
  1h=0.01sec *2 (No) 0.00-655.35 (0.00)
 
1h=1 unit
(Yes) 0-±2000000000 (0)
0.01-Max. rotation speed
  1h=0.01 r/min (No)
(0.01)
Acceleration time
Deceleration time
5204
5205
 
 
1h=0.1 ms (No) 0.0-99999.9 (0.0)
Positioning
data (divided)
Positioning status
+ M code
52E0
・ ・
・ ・
・ ・
Positioning
  status: Refer to (Yes) M code: 0-FFh (FFh)
[Table 5-5].
Stop timer
Data
15 Stop position
52E1
52E2
  1h=0.01sec *2 (No) 0.00-655.35 (0.00)
 
1h=1 unit
(Yes) 0-±2000000000 (0)
Rotation speed
52E3
0.01-Max. rotation speed
  1h=0.01 r/min (No)
(0.01)
Acceleration time
Deceleration time
52E4
52E5
 
 
1h=0.1 ms (No) 0.0-99999.9 (0.0)
Positioning
D000-
data
Positioning data 1-15 D00E
 
Refer to [5-4].
(Batch)
(*1) By setting PA1_31 (selection of deviation unit), 0 and 1 are defined as unit amount and pulse, respectively.
(*2) By setting PA2_42 (stop timer decimal position), 0 represents 0.01 sec, and 1 represents 0.001 sec.
[Table 13-2] Free data address list
Data type
Data name
PA3_41 assignment
Free PA3_42 assignment
assignment
data PA3_43 assignment
PA3_44 assignment
Address
(hex.)
6000-
6003
6004-
6007
6008-
600B
600C-
600F
Applicable FC
03h, 10h
17h
(*)
(*) Refer to the "Table 13-3 Assigned parameter list" for details.
Format
(with a sign)
Based on assigned
parameters (*)
Setting range
(default value)
Based on assigned
parameters (*)
Refer to Chapter 4 for details on settings PA3_41 to 44.
13-18 Modbus RTU Communications