CHAPTER 13 RS-485 COMMUNICATIONS
<Response message example>
Station No.
1byte 01
FC
1byte 17
No. of data bytes 1byte 0C
00 ・・・ Feedback speed: 1000 [r/min] (3E8h)
Data 1
4byte
00
03
E8
00 ・・・ Effective torque: 80 [%] (50h)
Information
Data 2
4byte
00
00
50
00 ・・・ Motor current: 80 [%] (50h)
Data 3
4byte
00
00
50
CRC check
16 bits 19
(2 bytes) 5F
FC 08h (Echo back maintenance )
(1) Query from the master
Station No.
FC
1 byte
1 byte
Information
Sub code
Data
2 bytes
2 bytes
CRC check
16 bits
(2 bytes)
・・・ 08h
(H) ・・・ Specify 0000h as the sub code of echo back.
(L)
(H) ・・・ Specify an arbitrary data.
(L)
(L)
(H)
(2) Response message from the amplifier
Station No.
FC
Information
Sub code
Data
CRC check
1 byte
1 byte
2 bytes
2 bytes
16 bits
(2 bytes)
・・・ 08h
(H) ・・・ 0000h
(L)
(H) ・・・ Echo back the specified data.
(L)
(L)
(H)
13