CHAPTER 13 RS-485 COMMUNICATIONS
13
Data1 (=A5h)
Data2 (=02h)
OUT13
1 (ON)
0
OUT12
0 (OFF)
0
OUT11
1 (ON)
0
OUT10
0 (OFF)
0
OUT9
0 (OFF)
0
OUT8
1 (ON)
0
OUT7
0 (OFF)
OUT15
1 (ON)
OUT6
1 (ON)
OUT14
0 (OFF)
FC 05h (Write in single coil data)
(1) Query from the master
Station No.
FC
1 byte
1 byte
Information
Address
Coil data
2 bytes
2 bytes
CRC check
16 bits
(2 bytes)
・・・ 05h
(H) ・・・ Specify the coil address.
(L)
* For the addresses, refer to the table 13-4.
(H) ・・・ Specify 000h for OFF and FF00h for ON.
(L)
(L)
(H)
(2) Response message form the amplifier
Station No.
FC
Information
Address
Coil data
CRC check
1 byte
1 byte
2 bytes
(H)
(L)
2 bytes
(H)
(L)
16 bits (L)
(2 bytes) (H)
・・・ 05h
・・・ Specified address.
・・・ Specified data.
(3) Message examples
Shows a message example to write in ON to OUT9 signal.
<Query example>
Station No.
FC
1 byte
1 byte
Information
Address
No. of coil data
2 bytes
2 bytes
CRC check
16 bits
(2 bytes)
01 ・・・ When the amplifier station no. is "1".
05
02 ・・・ Specify 0208h as the CONT9 signal address.
08
FF ・・・ Specify ON = FF00h.
00
0C
40
13-10 Modbus RTU Communications