CHAPTER 13 RS-485 COMMUNICATIONS
Set existence and logic of a parity and a stop bit length.
Characters are organized for each setting as follows:
LSB
MSB
PA2_93
0
1
2
3
4
5
6
7
8
9 10 11
0, 1 Start
Data (8 bits)
Parity Stop
2 Start
Data (8 bits)
Stop
3, 4 Start
Data (8 bits)
Parity Stop (2 bits)
5 Start
Data (8 bits)
Stop (2 bits)
(4) Response time and communication time over
No.
Parameter name
Setting range
PA2_94
PA2_95
Response time
Communication
time over
0.00 to 1.00 [s] (*)
0.00 [s]: No detection
0.01 to 9.99 [s]
Default
value
0.00
0.00
Change
Always
Always
(*) Actual response time is set to PA2_94 setting or {time for 3 characters + amplifier’s processing time},
whichever is longer.
Set the response time and communication time over parameters if needed.
For details, refer to pages 13-34 (response time) and 13-35 (communication time over).
13
Modbus RTU Communications 13-3