CHAPTER 12 POSITIONING DATA
12.3 Startup
Operation with positioning data
It is able to register 15 sets of positioning data in the servo amplifier.
Register the positioning data described in section 12.2.1 from the PC Loader or keypad, and set
address numbers according to the table below:
Positioning is started at the ON edge of the start positioning [START] signal.
Even if homing or position presetting has not been complete, the start positioning signal is
enabled.
Address No. selection table
Address
AD3 AD2 AD1
No.
0
OFF OFF OFF
1
OFF OFF OFF
2
OFF OFF ON
3
OFF OFF ON
4
OFF ON OFF
5
OFF ON OFF
6
OFF ON ON
7
OFF ON ON
8
ON OFF OFF
9
ON OFF OFF
10
ON OFF ON
11
ON OFF ON
12
ON ON OFF
13
ON ON OFF
14
ON ON ON
15
ON ON ON
AD0
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Sequential start
selection:
PA2_41
0: Disable
1: Enable
2: Homing
3: Immediate
value data
operation
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Operation mode
Address error
Sequential startup
Homing
Immediate value data operation
Operation with positioning data 1
Operation with positioning data 2
Operation with positioning data 3
Operation with positioning data 4
Operation with positioning data 5
Operation with positioning data 6
Operation with positioning data 7
Operation with positioning data 8
Operation with positioning data 9
Operation with positioning data 10
Operation with positioning data 11
Operation with positioning data 12
Operation with positioning data 13
Operation with positioning data 14
Operation with positioning data 15