CHAPTER 12 POSITIONING DATA
12.2.1.3 Stand still timer (stop time)
After the motor has reached a specified position of the positioning data, when the set time of the stand
still timer has passed, the in position [INP] signal is output outside. (It is impossible to set the stand
still timer on immediate value data.)
This timer can be set from 0.00 to 655.35 s in increments of 0.01 s.
By changing the setting of the PA2_42 decimal point position of stand still timer, it is also allowed to
set from 0.000 to 65.535 s.
Stand still timer of positioning data
Position data (stop position)
Rotation
speed
No. 5 (M code : 20)
Ready
ON
Start
positioning
OFF
ON
AD3-AD0
5
9
Speed data (rotation speed)
Stand still timer
(stop time)
Time
In position
ON
OFF
ON
(lNP)
M code (output
FF
20
FF
at startup)
Positioning data are regarded as being executed while the timer is measured.
The default value of the M code is "FF" (changeable into "00" by PA2_43).
12
12.2.1.4 Acceleration time and deceleration time
Set an acceleration/deceleration time of the servo motor.
Setting value of the acceleration/deceleration time is a time setting before reaching 0 to 2000 r/min.
However, if the setting is 0.0 (default value), as shown in the table below, the motor follows the
acceleration/deceleration time is set by parameters by turning ON/OFF ACC0.
ACC0 (14)
OFF
ON
Acceleration time
PA1_37
PA1_39
Deceleration time
PA1_38
PA1_40
For details of acceleration time and deceleration time, refer to “PA1_36 to 40 Acceleration time and
deceleration time settings” in CHAPTER 4 on page 4-21.
12-8 Settings