CHAPTER 10 PERIPHERAL EQUIPMENT
Monitor (CN4)
A measuring instrument or similar is connected to the connector 4 (CN4) of the servo amplifier.
The signal of this connector is analog output voltage for measuring instrument and is not necessary
for servo amplifier operation.
This connector is not prepared as option.
1 MON1 3 M5(0 V)
2 MON2 4 M5(0 V)
3
1
4
2
Model and manufacturer
Crimp socket
DF11-4DS-2C
Crimp terminal DF11-2428SC
Hirose Electric Co., Ltd.
External regenerative resistor (1)
Model: WSR-401
Applicable range: servo amplifier model: RYH201F5-VV2, RYH401F5-VV2
182.5±1.5
172±1
150±1
1000
+100
0
20±0.3
Item
Model
Resistor
Resistance
Allowable power
Operating temperature
Thermistor
Dielectric strength
Contact capacity
* Thickness ofthe installedsection:1.2 mm
Specifications
WSR-401
68 Ω
17 W (cont.)
Open at 135 ±10°C
For 1 minutes at 1.5 kV AC
30 VDC 3 A
10
Connect the regenerative resistor to the servo amplifier with a 10 m or shorter cable.
The external regenerative resistor becomes hot. Keep flammable matters away from the
external regenerative resistor.
For connection of the external regenerative resistor, refer to "10.8 External Regenerative
Resistor."
Optional Equipment 10-37