CHAPTER 10 PERIPHERAL EQUIPMENT
10.8 External Regenerative Resistor
The external regenerative resistor consumes regenerative power generated by the servomotor.
Use an external regenerative resistor if the elevating load is large and the operation frequency is
high.
Servo amplifier model
Built-in
Regenerative
resistor*
External
Regenerative
Resistor
Applicable
resistance [Ω]
RYH201F5-VV2
-
WSR-401
39 to 180
RYH401F5-VV2
-
(17W/68Ω)
39 to 90
RYH751F5-VV2
RYH152F5-VV2
20W/40Ω
20W/15Ω
WSR-152
(50W/15Ω)
13 to 47
8.2 to 27
RYH202F5-VV2
RYH302F5-VV2
45W/12Ω
DB11-2
(260W/10Ω)
8.2 to 20
8.2 to 13
RYH402F5-VV2
RYH502F5-VV2
60W/6Ω
DB22-2
(300W/5.8Ω)
3.9 to 8.2
3.9 to 6.8
* The allowable wattage of the built-in regenerative resistor varies according to the ambient
temperature.
Block diagram of main circuit section (Frame 1)
ExtEexrntearl nRael gBernaekriantgive
RReessiissttoor r
RB2
RB1
(+)
L1
L2
L3
(-)
FUSE
Inrush
current
suppression
resistor
Servo amplifier
Servomotor
10
Servomotor
Use the external regenerative resistor in the designated set without fail.
There is a risk of fire.
External Regenerative Resistor 10-19