CHAPTER 7 MAINTENANCE AND INSPECTION
7.6 Approximate Replacement Timing
The approximate replacement timings of parts for the following operating conditions are shown below.
However, note that the timing varies according to the operation method, environmental conditions and
so on. For the replacement method, contact us.
[Operating conditions]
Ambient temperature:
Load factor:
Operation rate:
Annual average 30°C
Within 80%
Within 20 hours/day
Servomotor
Part name
Standard service life
Method
Bearing
20,000 to 30,000 hours Send the product back
Oil seal
5,000 hours
to us for repair.
7
Servo amplifier
Part name
Standard service life
Method
Capacitors of main circuit
73,000 hours
Aluminum electrolytic capacitors
of printed circuit board
Cooling fan
73,000 hours
73,000 hours
Send the product back
to us for repair.
Fuse
73,000 hours
Battery for absolute system
35,000 hours *1 Replace with a new part.
*1 Cumulative operation hours without tuning the power on
Approximate Replacement Timing 7-19