CHAPTER 7 MAINTENANCE AND INSPECTION
Alarm reset
Some alarms cannot be cleared through alarm resetting. To remove the alarm that is not cleared
through alarm resetting, remove the cause of the alarm following the method described in "7.3
Troubleshooting Method" after (or before) the power is turned off, and then reset the status by
turning the power again.
Alarms cleared through alarm resetting
Alarms not cleared through alarm resetting
display
Name
display
Name
oc1
Overcurrent 1
Et1
Encoder Trouble 1
oc2
Overcurrent 2
Et2
Encoder Trouble 2
oS
Overspeed
ct
Circuit Trouble
Hu
Overvoltage
tH
Breaking Transistor
Overheat
Ec
Encoder Communication
Error
oL1
Overload 1
dE
Memory Error
Fb
Fuse Blown
cE Motor Combination Error
ctE CONT(Control signal)Error
oL2
Overload 2
LuP Main Power Undervoltage
rH1
Internal Breaking Resistor
Overheat
rH2
External Breaking Resistor
Overheat
oF
Deviation Overflow
rH3 Breaking Transistor Error
rH4
Inrush Current Suppression
Circuit Trouble
7
dL1 Absolute Data Lost 1*
DL2 Absolute Data Lost 2*
DL3 Absolute Data Lost 3*
AH
Amplifier Overheat
AF Multi-turn Data Over Flow*
EH
Encoder Overheat
iE
Initial Error
* The alarms dL1 to 3 and AF can be
Alarm reset at keypad
canceled by position preset.
The alarm currently detected at the servo amplifier is reset.
Fn05
ESC
SET
(1 sec. or over)
ALrt
SET
(1 sec. or over)
Go
ESC
donE End of resetting
Status Display 7-5