CHAPTER 6 KEYPAD
(13) Profile operation
Operate the servomotor continuously. Once started, reciprocal operation (depending on parameter
PA1_23) continues until operation is stopped.
Continuous operation is possible even if cables to the host control unit are not connected. Use this
mode to check the effective torque or for other purposes.
Operation
pattern name
Profile
operation
Travel
distance
PA1_20
Operation Acceleration Deceleration Rotation
frequency
time
time
speed
Endless
PA1_37
PA1_38
PA1_21
Timer
PA1_22
Direction of rotation
Go path
Return
path
PA1_23
ESC
ESC
Returns by
pressing ESC.
Fn13
SET
(1 sec. or over)
ESC
Ptn
SET
(1 sec. or over)
_Ptn
nG *
6
Operation stop
completion
_StP
SET
(1 sec. or over)
Ends prematurely
by pressing ESC.
8Ptn
During profile operation
The lit arrow moves along a figure of
eight.
*[Cause of NG1 indication]
Operation is disabled due to EMG detection or alarm detection.
During motor rotation.
[Cause of NG2 indication]
Operation is stopped due to ±OT detection, EMG detection, S-ON signal OFF, and alarm
detection, etc.
Test Operation Mode 6-53