CHAPTER 6 KEYPAD
(8) Positioning data initialization
Fn08
ESC
SET
(1 sec. or over)
Po.in
SET
(1 sec. or over)
Go
The positioning data are initialized.
After initializing, turn the power off then on again.
SET
(1 sec. or over)
ESC
nG
* For the cause of NG display, refer
to "NG display (common)" on page
6-43.
ESC
donE
6
(9) Auto offset adjustment
The current input voltage supplied at the analog
Fn09
speed/torgue command voltage input [VREF] / [TREF]
terminal is reset to 0 V.
ESC
SET
(1 sec. or over)
SET
(1 sec. or over)
A.off
nG
SET
(1 sec. or over)
ESC
* For the cause of NG display, refer
to "NG display (common)" on page
6-43.
Go
ESC
donE
End of offsetting
If both the X1 and X2 terminals of multi-step speed selection are turned off with the FWD (REV)
signal, the output shaft of the servomotor rotates according to the analog speed command voltage.
The output shaft of the servomotor may rotate at a small speed even if the speed command
voltage is 0 V.
Use the "zero clamp function (parameter PA3_35)" when necessary.