CHAPTER 6 KEYPAD
6.6 Maintenance Mode
In the maintenance mode, detected alarms, total time - main power supply and so on are displayed.
Press the [MODE/ESC] key until [En01] is displayed and press and hold the [SET/SHIFT] key for at
least one second to display data.
En01
En02
En03
: Alarm at present
: Alarm history
: Warning at present
En04 : Total time - main power supply
En06 : Motor running time
(1) Alarm at present
The alarm detected currently is displayed in a code.
If the alarm reset is executed, the display will automatically return to the initial one.
After an alarm is detected, the following is displayed automatically. Supplementary data to the
alarm can be displayed, too.
6
En01
ESC
SET (1 sec. or over)
oL1
ESC
SET (1 sec. or over)
rc01
rc02
rc03
∧/∨ rc04
rc05
rc06
rc07
rc08 (Total time-main power
supply)
Unused
rc09
(Motor running time)
rc10
(Feedback speed)
(Feedback speed before
five min)
rc11
rc12
(Command speed)
(Command torque)
rc13
(Motor current)
(Effective torque)
(DC link voltage)
(EC error count)
(Command position)
(Sequence mode)
∧/∨
SET (1 sec. or over)
9999
6-28 Maintenance Mode