CHAPTER 6 KEYPAD
(26) Settling time (displayed digits: unsigned five digits) U/L
on26
SET
(1 sec. or over)
----
The settling time under position control is displayed.
The displaying range is from 0 to 1000.0 ms. If the settling
time exceeds 1000.0 ms, "1000.0 is displayed.
ESC
Blinks three times.
1
SHIFT
----
Blinks three times.
6
ESC
000.0
(27) Resonance frequency 1 (displayed digits: unsigned four digits)
on27
The resonance frequency recognized by the servo
amplifier is displayed.
ESC
SET
(1 sec. or over)
2000
The displaying range is from 50 to 2000 Hz. If no
resonance is detected, "4000" is displayed.
(28) Resonance frequency 2 (displayed digits: unsigned four digits)
on28
The resonance frequency recognized by the servo
amplifier is displayed.
ESC
SET
The displaying range is from 50 to 2000 Hz. If no
(1 sec. or over) resonance is detected, "4000" is displayed.
2000
6-26 Monitor Mode