CHAPTER 6 KEYPAD
(21) OL thermal value (displayed digits: unsigned three digits)
on21
The load ratio to the load alarm level is displayed in
percent. An overload alarm is caused if this value reaches
ESC
SET
100. The minimum increment is 1. The displaying range is
(1 sec. or over) from 0 to 100%.
100
(22) Regenerative resistor thermal value (displayed digits: unsigned three digits)
on22
The regeneration load ratio to the regenerative resistor
overheat alarm level is displayed in percent. A regenerative
ESC
SET
resistor overheat alarm is caused if this value is 100. The
(1 sec. or over) regeneration load ratio is calculated for amplifier frame
100
no.2 or above if PA2_65 (regenerative resistor selection) is
set at 1 (internal resistor).
6
The minimum increment is 1. The displaying range is from
0 to 100%.
(23) Power (w) (displayed digits: signed three digits)
on23
The servomotor power (w) is displayed in percent to the
rating.
ESC
SET
The data is displayed in the range from 0 to 900% in
(1 sec. or over) increments of 1.
300
With a negative data
-300
(24) Motor temperature (displayed digits: unsigned three digits)
on24
The servomotor temperature is displayed. The range from
0 to 120°C is displayed in increments of 1°C.
ESC
SET
(1 sec. or over)
120
6-24 Monitor Mode