CHAPTER 6 KEYPAD
(12) Command cumulative pulse (displayed digits: signed 10 digits) U/L
ESC
on12
SET
(1 sec. or over)
----
Blinks three
times.
99
The number of pulses supplied to the pulse input terminal
is displayed. The cumulative value increases upon forward
direction pulses, while it decreases upon reverse direction
pulses. With two signals at A/B phase pulse, each edge is
counted (multiple of four). The count increases upon
B-phase advance.
With a negative data
- 99
SHIFT
6
----
Blinks three times.
ESC
9999
With a negative data
9999
-999
SHIFT
The figure and "-" symbol are displayed alternately.
----
Blinks three times.
ESC
9999
With a negative data
9999
-999
The figure and "-" symbol are displayed alternately.
Press and hold the [] and [] keys simultaneously for at least one second to reset the
feedback cumulative pulses.
6-20 Monitor Mode