CHAPTER 6 KEYPAD
(2) Amplifier setting U/L
The servo amplifier control function, interface format and capacity are displayed.
Sn02
SET (1 sec. or over)
----
Indication
u 2nd digit
Control
Speed control
ESC
Blinks three times.
ud
Indication
d 1st digit
SHIFT
Interface
DI/DO
standard
6
----
Indication
ESC
500 Blinks three times.
…
Capacity
0.05 kW
500
152 1.5 kW
(3) Motor setting U/L
The type of servomotor connected to the servo amplifier, capacity and encode type are displayed.
Sn03
Indication
b 3rd digit
G
c
S
Motor type
GYB
GYG
GYC
GYS
SET (1 sec. or over)
----
Indication
Interface
6 1st digit
18-bit ABS
Blinks three times.
ESC
S-7
7 20-bit INC
9 17-bit INC
SHIFT
----
Indication
Rated output capacity
ESC
500 Blinks three times.
0.05 kW
500
…
302 3.0 kW
6-12 Sequence Mode