CHAPTER 4 PARAMETER
Parameter assignment corresponding address configuration and assignment No. details are as follows.
Please note that the default value of 00000000 indicates the feedback speed.
4
Corresponding addresses:
No.
PA3_41 00
Settingrange
00 00 00
Coardredsrepsosnedsing
6000H
6001H
6002H
6003H
No.
Setting range
PA3_42 00 00 00 00
Coardredsrepsosnedsing
6004H
6005H
6006H
6007H
No.
Settingrange
PA3_43 00 00 00 00
No.
Setting range
PA3_44 00 00 00 00
Coardredsrepsosnedsing
6008H
6009H
600AH
600BH
Coardredsrepsosnedsing
600CH
600DH
600EH
600FH
These settings are valid only for addresses 6000H to 600FH.
If function code (FC) 17H is used:
Set as read and write data for parameters PA3_41 to PA3_42 (corresponding address area 6000H
to 6007H), and as read data for parameters PA3_41 to PA3_44 (corresponding address area 6000H
to 600FH).
An exception code (02h) is returned if other than the above is set.
If the same address is specified for both read data and write data, read out data is taken to be the
same as write in data (value on this occasion).
Set at least one item of read and write data. If less than this, an exception code (03h) is returned.
If function code (FC) 03H is used:
Set read data for parameters PA3_41 to PA3_44 (corresponding address area 6000H to 600FH).
An exception code (02h) is returned if other than the above is set.
If function code (FC) 10H is used:
Set write data for parameters PA3_41 to PA3_42 (corresponding address area 6000H to 6007H).
An exception code (02h) is returned if other than the above is set.
Refer to the following items in Chapter 13 for detailed settings.
3. Function codes (FC) ---------------FC 17h (Read out/write in various data)
4. Addresses ----------------------------Data addresses
4-100 Input Terminal Function Setting Parameter