CHAPTER 4 PARAMETER
PA2_72 Station number
No.
Name
Setting range
72 Station number
Station No.: 1 to 31
Specify the station number of the amplifier.
RS-485 type: Specify the station number of each station.
PA2_73 Communication baud rate (RS-485)
Default value Change
1
Power
No.
Name
Setting range
Default value Change
4
73
Communication baud rate
(RS-485)
0: 38400 [bps]
2: 9600 [bps]
1: 19200 [bps]
3: 115200 [bps]
Specify the communication baud rate of the system combined over RS-485.
0
Power
PA2_74 Parameter write protection
No.
Name
Setting range
74 Parameter write protection 0: Write enable 1: Write protect
Specify parameter write protection.
Enter "1" to prohibit parameter editing. Only this parameter can be changed.
PA2_75 Positioning data write protection
No.
Name
Setting range
75
Positioning data write
protection
0: Write enable 1: Write protect
Specify positioning data write protection.
Enter "1" to prohibit positioning data editing.
Default
value
0
Change
Always
Default
value
Change
0
Always
4-88 Extended Function Setting Parameter