CHAPTER 4 PARAMETER
[Reference example]
Example: Timing chart
To hold deviation at TL (TREF)
(Torque limit 1 = OFF, Torque limit 0 = ON)
TL
Torque
limit
150%
200%
50%
Internal
torque limit
150%
Deviation is held if the
torque is limited.
50%
Contact stop timing
Forward rotation torque limit
Reverse rotation torque limit
Time
Forward rotation torque limit
Reverse rotation torque limit
Time
Speed
Position
deviation
Deviation
reset
Position deviation is held.
Reset the position deviation
with a customer's device.
OFF
ON
4
PA2_61 to 63 Action sequence settings
No.
Name
61
Action sequence at
servo-on OFF
62
Action sequence at
alarm
63
Action sequence at
main power shutoff
Setting range
3: Free-run at deceleration, free-run at stop
5: Emergency stop at deceleration /, free-run at stop
3: Free-run at deceleration, free-run at stop
5: Emergency stop at deceleration / (*1), free-run at
stop
3: Free-run at deceleration, free-run at stop
5: Emergency stop at deceleration /, free-run at stop
Default
value
Change
5 Power
5 Power
5 Power
Extended Function Setting Parameter 4-85