CHAPTER 4 PARAMETER
(2) Area OFF ON (If PA2_31 (point detection, area detection) is 1)
The signal is turned on if the current position is exactly or larger than the setting of the standard
parameter.
It is turned off if the position is less than the setting.
Point detection, area detection position 1
(PA2_32)
Point detection, area detection position 2
(PA2_33)
(Standard parameter 64)
Current position
190.0
200.0 210.0
Area
OFF
ON
(3) Area ON OFF (If PA2_31 (point detection, area detection) is 2)
The signal is turned on if the current position is exactly or less than the setting of the standard
parameter.
It is turned off if the position exceeds the setting.
Point detection, area
(PA2_32)
Point detection, area
(PA2_33)
detection position 1
detection position 2
190.0
200.0 210.0
Current position
Area
ON
OFF
4
Automatic Operation Setting Parameter 4-75