CHAPTER 4 PARAMETER
1: Positioning Repetitive rotation in the same direction can be made.
start with The position is preset at the start, and all position data is handled as an
zero position incremental value. The OT function, software OT and hardware OT functions
preset:
allocated to input signals are disabled.
PA2_28 to 29 Limiter detection position
No.
Name
Setting range
Default value Change
28
Positive Iimiter detection
position
-2000000000 to 2000000000 [units]
29
Negative Iimiter detection
position
Enter the position of the limiter detection function.
2000000000
Always
-2000000000
4
While each setting can be positive or negative, the setting of PA2_28 must not be smaller than the
setting of PA2_29.
For detail description of limiter detection, refer to “CHAPTER 2 WIRING.”
Automatic Operation Setting Parameter 4-73