CHAPTER 3 OPERATION
3.4.10 Positioning Data Operation
Enter “1” to parameter PA2_40 (internal positioning data selection) to perform positioning data
operation. PTP (point-to-point) positioning operation is made according to Di/Do signals or commands
sent via RS-485 communications.
When in-position [INP] is active, enter the desired positioning address (AD0 to AD3) and turn start
positioning [START] on (activating edge) to execute positioning.
The positioning data can be registered with the PC Loader or keypad (front panel of amplifier) or
3
through teaching. To enable positioning data operation, you can allocate “77” (positioning data
selection) to a CONT signal and turn the signal on.
For details, refer to “CHAPTER 12 POSITIONING DATA.”
Speed
Positioning data
No.7
Stand still timer
Positioning data
No.15
Stand still timer
Time
[RDY]
[INP]
M code output
Positioning
address
[START]
ON
ON
OFF
FF
7
OFF
ON
OFF
ON
7
15
ON
ON
15
OFF
Operation 3-19