CHAPTER 3 OPERATION
3.4.7 Homing
When in-position [INP] is turned on, activation of the homing command [ORG] starts a homing motion.
Enter parameters PA2_06 through 18 and 24 to configure the homing pattern.
Speed
Homing speed
Homing
creeping speed
Shift amount for
3
homing
Time
[RDY]
ON
[INP]
Home position
LS detection
ON
OFF
Homing completion
OFF
ON
ON OFF
OFF
ON
[ORG]
OFF ON
OFF
[LS]
OFF
ON
OFF
Encoder Z-phase
OFF
ON
OFF
For details of the homing pattern settings, refer to “CHAPTER 4 PARAMETER.”
The homing motion can be interrupted with forced stop [EMG].
The in-position [INP] signal shown in the figure assumes the level output mode.
If positioning completion single shot output is selected at the parameter PA1_33, check for
stoppage with an external circuit before executing operation.
Operation 3-15