CHAPTER 3 OPERATION
3.2 Selection of Operation Procedure
The VV type servo amplifier is capable of speed control and torque control with analog voltages,
position control with pulse, positioning data operation with Di/Do signals or RS-485 communications,
and immediate value data operation with RS-485 communications.
Follow the flow chart below to select the desired operation and enter parameters, etc.
START
Positioning operation
No
with amplifier alone?
Yes
Enter “7” to PA1_01
(control mode selection).
Operation in FALDIC-α
series-compatible mode?
Yes
No
Positioning control with
speed control, torque control
or pulse is used.
Enter “6” to PA1_01
(control mode selection).
Enter “1” to “5” to PA1_01
(control mode selection).
3
Positioning operation
with internal data?
Yes
No
Immediate value positioning
operation is necessary.
Enter “1” to PA2_40
(internal positioning data selection).
Enter “0” to PA2_40
(internal positioning data selection).
Positioning operation for up to 15
points can be made according to
internal data.
Refer to pages 3-15
through 18.
Positioning operation can be made
according to RS-485 (Modbus-RTU or PC
Loader) communications.
Operation can be made with the
same host settings as those of
FALDIC-α Series.
Refer to pages 3-15
through 17 and 3-19.
Refer to pages 3-13
through 19.
(Immediate value data +
startup command)
Operation can be made
according to analog voltages
and pulse commands.
Refer to page 3-12.
③④
Selection of Operation Procedure 3-3