CHAPTER 2 WIRING
Relevant description
(1) M code setting range
Enter the M code in a binary between 00h and FFh.
(2) Output at start (output in start) / output at completion (output after completion)
You can select the M code output timing between during execution of positioning data (output at
2
start) and after execution of positioning data (output at completion).
Output at start (in-process output)
The signal is issued since the start of the positioning motion to the end. After the positioning motion
is finished, the signal is turned off.
Simultaneous output of M code
Rotation
speed
M code 20
Ready for
servo-on
ON
Start
positioning
OFF
ON
AD3 to AD0
5
15
In-position
ON
(level)
M code
FF
OFF
20
* Positioning data is executed while the timer time is counted.
* The default value of the M code is FF.
Stand still timer
(positioning data)
ON
FF
Time
Description of I/O Signals 2-81