CHAPTER 2 WIRING
Parameter setting
To assign the edit permission to a sequence input terminal, specify the corresponding value ("55")
to the input terminal function setting parameter.
Relevant description
(1) Parameter write protection
Specify "1" (write protection) to PA2_74 (parameter write protection) to disable key operation at the
2
keypad and parameter editing at the PC Loader.
The relationship between the edit permission and PA2_74 (parameter write protection) is shown in
the table below.
Edit permission
PA2_74
Parameter change operation
Edit permission
response
Not assigned 0 : Write enable
ON
ON (Possible)
OFF
0 : Write enable
OFF
OFF (Impossible)
ON
0 : Write enable
ON
ON (Possible)
Not assigned 1: Write protect
OFF
OFF (Impossible)
OFF
1: Write protect
OFF
OFF (Impossible)
ON
1: Write protect
OFF
OFF (Impossible)
(2) Edit permission response
The edit permission response is an output signal.
The signal is output if it is assigned to an output signal and the edit permission is turned on.
To assign the edit permission response to a sequence output terminal, specify the corresponding
value ("29") to the output terminal function setting parameter.
Description of I/O Signals 2-55