Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
CANopen Mode
Object 1016h: Consumer heartbeat time
Index
Name
Object code
Data type
Access
PDO mapping
1016h
Consumer heartbeat time
ARRAY
UNSIGNED32
RW
No
12
Sub-index
Description
Data type
Access
PDO mapping
Setting range
Default
0
Number of sub-index
UNSIGNED8
RO
No
1
1
Sub-index
Description
Data type
Access
PDO mapping
Setting range
Default
1
Consumer heartbeat time
UNSIGNED32
RW
No
UNSIGNED32
0
Object function:
Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit
Bit 0 - Bit 15
Bit 16 - Bit 23
Bit 24 - Bit 31
Function
Heartbeat time
Node-ID
Reserved
Description
UNSIGNED8; unit: ms
UNSIGNED8
-
Consumer heartbeat time is defined as the time the servo drive expects to receive a
heartbeat. When the heartbeat consumer does not receive the heartbeat signal within the
receiving time, it triggers the heartbeat event, meaning AL180 is triggered. The consumer
heartbeat time must be greater than the producer heartbeat time. Since there are delays and
other uncontrollable external factors in transmitting the heartbeat message, you must retain a
tolerance time for the transmission.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
12-41