ASDA-A3
9
9.3 Modbus communication protocol
There are two modes of Modbus network communication: ASCII (American Standard Code for
Information Interchange) and RTU (Remote Terminal Unit). You can set the communication
protocol (ASCII or RTU) with P3.002 according to your requirements. The ASDA-A3 servo drive
also supports these functions: accessing multiple words (03H), writing single word (06H), and
writing multiple words (10H). Refer to the following descriptions.
Code description
ASCII mode:
In ASCII mode, data is transmitted in ASCII (American Standard Code for Information
Interchange) format. For instance, to transmit “64H” between the master and slave, the ASCII
codes “36H” and “34H” are sent to represent ‟6” and “4” respectively.
Note: the servo drive does not support the broadcast mode.
The corresponding ASCII codes for the numbers 0 to 9 and the characters A to F are as follows:
Symbol
ASCII code
Symbol
ASCII code
‘0’
‘1’
‘2’
‘3’
‘4’
‘5’
‘6’
‘7’
30H 31H 32H 33H 34H 35H 36H 37H
‘8’
‘9’
‘A’
‘B’
‘C’
‘D’
‘E’
‘F’
38H 39H 41H 42H 43H 44H 45H 46H
RTU mode:
Each data frame consists of an 8-bit character (hexadecimal), which is more efficient than ASCII
mode for data transmission because it can be done without code interchange. For instance,
when transmitting “64H” between the master and slave, simply send “64H”.
9-4