Parameters
Value: 0x0D
DI name
Description
Triggering
method
Clear function of analog Position command. If this DI is on, the position
of the motor is held at the current position when DI is triggered. Despite
the change in the analog command during DI is on, the motor remains
at the current position even when the DI is off. However, the position
that the motor remains at corresponds to the new analog command.
Thus, the analog input command redefines the position system of the
motor.
Control
mode
Motor position
(Turn)
8
VPRS
Motor
position
when DI is
triggered
When DI is on, all
input commands
are cleared
Voltage when DI
is triggered
Analog input
command (V)
When DI is off, motor
does not move, but the
zero point of the position
system is redefined
Analog input
command (V)
Level
triggered
PT
Value: 0x0E
DI name
Description
FEC
When the servo drive is in full-closed loop mode and this DI is on, the
error between the main encoder and the auxiliary encoder is cleared.
Triggering Control
method mode
Rising- PT/PR full-
edge closed
triggered loop
Value: 0x0F
DI name
Description
Switch between P1.040 (Maximum motor speed for analog Speed
SPDKVC command 1) and P1.081 (Maximum motor speed for analog Speed
command 2).
Triggering Control
method mode
Level
triggered
S
Value: 0x10
DI name
Description
SPDLM
In Torque mode, motor speed is limited when this DI is on, and source
of the Speed limit command is the internal register or analog voltage.
Triggering
method
Level
triggered
Control
mode
T