Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
PM.051Linear motor phase inductance
Operation
interface:
Panel
/
software
Default: -
Communication
-
Unit: mH
0.01 mH
Setting range: 0.00 to 1000.00
0 to 100000
Format: Two decimals
DEC
Example: 1.5 = 1.5 mH
150 = 1.5 mH
Address: FD66H
FD67H
Applicable
motor:
Linear
motor
Data size: 32-bit
Settings:
Input the correct value according to the specifications of the linear motor.
PM.052
Reserved
PM.053Linear motor back electromotive force constant
Address: FD6AH
FD6BH
Operation
interface:
Panel
/
software
Communication
Applicable
motor:
Linear
motor
Default: -
-
Data size: 16-bit
Unit: Vrms/(m/s)
0.1 Vrms/(m/s)
Setting range: 0.0 to 591.2
0 to 5912
Format: One decimal
DEC
Example: 1.5 = 1.5 Vrms/(m/s) 15 = 1.5 Vrms/(m/s)
Settings:
Input the correct value according to the specifications of the linear motor.
PM.054 -
PM.063
Reserved
8-266
Send Quote Requests to info@automatedpt.com