Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
PM.048▲ Linear motor maximum speed
Default: -
Unit: mm/s
Format: DEC
Address: FD60H
FD61H
Applicable
motor:
Linear
motor
Setting range: 0 to 15999
Data size: 16-bit
Settings:
Input the correct value according to the specifications of the linear motor.
8
PM.049▲ Linear motor force constant
Operation
interface:
Panel
/
software
Default: -
Communication
-
Address: FD62H
FD63H
Applicable
motor:
Linear
motor
Data size: 32-bit
Unit: N/Arms
0.01 N/Arms
Setting range: 0.00 to 1773.62
0 to 177362
Format: Two decimals
DEC
Example: 1.5 = 1.5 N/Arms
150 = 1.5 N/Arms
Settings:
Input the correct value according to the specifications of the linear motor.
PM.050▲ Linear motor phase resistance
Operation
interface:
Panel
/
software
Default: -
Communication
-
Unit: ohm
0.001 ohm
Setting range: 0.000 to 2000.000
0 to 2000000
Format: Three decimals
DEC
Example: 1.5 = 1.5 ohm
1500 = 1.5 ohm
Address: FD64H
FD65H
Applicable
motor:
Linear
motor
Data size: 32-bit
Settings:
Input the correct value according to the specifications of the linear motor.