Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
PM.045▲● Linear motor pole pitch (N-N)
Operation
interface:
Panel
/
software
Default: -
Communication
-
Address: FD5AH
FD5BH
Applicable
motor:
Linear
motor
Data size: 32-bit
Unit: mm/360° (mm/N-N) 0.001 mm/360° (0.001 mm/N-N)
Setting range: 1.000 to 500.000
1000 to 500000
Format: Three decimals
DEC
Example: 1.5 = 1.5 mm/360° 1500 = 1.5 mm/360°
Settings:
Input the correct value according to the specifications of the linear motor.
PM.046▲● Linear motor rated current
Operation
interface:
Panel
/
software
Default: -
Communication
-
Address: FD5CH
FD5DH
Applicable
motor:
Linear
motor
Data size: 16-bit
Unit: Arms
Setting
range:
0.00 to servo
rated current
drive
Format: Two decimals
Example: 1.5 = 1.5 Arms
0.01 Arms
0 to servo drive rated current x 100
DEC
150 = 1.5 Arms
Settings:
Input the correct value according to the specifications of the linear motor.
Unit conversion between Ampere peak and Ampere RMS:
Ampere peak (Apk)= Ampere RMS (Arms)×√2
PM.047▲● Linear motor maximum current
Operation
interface:
Panel
/
software
Default: -
Communication
-
Address: FD5EH
FD5FH
Applicable
motor:
Linear
motor
Data size: 16-bit
Unit: Arms
Setting
range:
0.00 to servo drive
maximum current
Format: Two decimals
0.01 Arms
0 to servo drive maximum current x 100
DEC
Example: 1.5 = 1.5 Arms
150 = 1.5 Arms
Settings:
Input the correct value according to the specifications of the linear motor.
Unit conversion between Ampere peak and Ampere RMS:
Ampere peak (Apk)= Ampere RMS (Arms)×√2
8-264
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com