ASDA-A3
Example 1:
Overload (AL006)
protection counter
100%
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
Load ratio
Load ratio
Operating level
160%
100%
40%
8
0%
T1
T2
T3
Time
1. When the load ratio is 160%, the overload (AL006) protection counter continues to increase.
2. When the load ratio is 100%, the operating level is leveled off.
3. When the load ratio is 40%, the overload (AL006) protection counter continues to decrease.
Example 2:
Overload (AL006)
protection counter
100%
Load ratio
AL006 occurs
Servo Off
Load ratio
Operating level
160%
140%
40%
0%
T1
T2
T3
Time
As shown in the preceding figure, the load ratio affects whether the load is accumulated. When the load
accumulates over 100%, the operating time must be taken into consideration, or else AL006 occurs.