Parameters
PM.005
Position signal converter box interpolation magnification
Address: FD0AH
FD0BH
Default: 11
Applicable motor: Linear motor, third-party rotary motor
Unit: -
Setting range: 2 - 11
Format: DEC
Data size: 16-bit
Settings:
This parameter improves the motor resolution with interpolation magnification. It is applicable to sine
wave encoders and not applicable to pulse encoders.
The resolution of the sine wave encoder after interpolation is PM.004 x 2N; N = PM.005.
8
PM.006▲● Motor UVW and Hall sensor phase sequences
Address: FD0CH
FD0DH
Default: 0x0000
Applicable motor: Linear motor, third-party rotary motor
Unit: -
Setting range: 0x0000 - 0x0011
Format: HEX
Data size: 16-bit
Settings:
During the motor parameter identification process, the servo drive automatically detects the phase
sequences of the motor UVW and Hall sensor. You can use this parameter to obtain this information.
X: motor UVW phase sequence and encoder incremental direction
0: when A phase is ahead of B phase, the motor phase sequence is U, V, and W.
1: when A phase is ahead of B phase, the motor phase sequence is U, W, and V.
X = 0
U phase V phase W phase
X = 1 U phase W phase V phase
Three-phase
back
electromotive
force of the
motor
Three-phase
back
electromotive
force of the
motor
Encoder
A phase
Encoder
B phase
Encoder
A phase
Encoder
B phase