Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
The servo drive automatically detects the identification status and inputs this parameter after executing
the motor parameter identification process.
Note: this parameter value is always 1 and unchangeable if you are using a Delta rotary motor.
PM.003▲● Encoder type
Default: 0x0010
Unit: -
Format: HEX
Settings:
Address: FD06H
FD07H
Applicable motor: All
Setting range: 0x0000 - 0x1312
Data size: 16-bit
8
UZ YX
X CN2 signal type
Y Hall sensor
Z Converter box ABZ pulse filter
U Main encoder signal source
X: CN2 signal type*2
0: pulse digital signal
1: sine wave analog signal
2: pulse digital signal - dedicated for Delta motor with magnetic encoder (ECMA-C8)
Y: Hall sensor
0: no Hall sensor
1: with Hall sensor
Important: if you set PM.003.Y to 0, the motor moves slightly to detect the magnetic pole when the servo is on
for the first time. It is suggested that you execute the Z-axis magnetic field detection after installing the Hall
sensor.
Z: converter box ABZ pulse filter*2
0: bypass
1: 16 MHz
2: 8 MHz
3: 3 MHz
Example: pulse width 16 MHz (62.5 ns)
62.5 ns
62.5 ns
U: main encoder signal source
0: CN2
1: CN5
Note:
1. This parameter is invalid if you are using a Delta communication type rotary motor.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-249