Parameters
P5.100
Data array: window #3 for reading and writing
Address: 05C8H
05C9H
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Window #3: when read or written by any method, the value set by P5.011 does not add 1.
Refer to Section 7.2.1 Data array for detailed instructions.
8
P5.101
Data array: window #4 for reading and writing
Address: 05CAH
05CBH
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Window #4: when read or written by any method, the value set by P5.011 does not add 1.
Refer to Section 7.2.1 Data array for detailed instructions.
P5.102
Data array: window #5 for reading and writing
Address: 05CCH
05CDH
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Window #5: when read or written by any method, the value set by P5.011 does not add 1.
Refer to Section 7.2.1 Data array for detailed instructions.
P5.103
Data array: window #6 for reading and writing
Address: 05CEH
05CFH
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Window #6: when read or written by any method, the value set by P5.011 does not add 1.
Refer to Section 7.2.1 Data array for detailed instructions.