Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
Z: the action when EV3 is on
0: no action
1 - D: execute PR# 51 - 63
U: the action when EV4 is on
0: no action
1 - D: execute PR# 51 - 63
P5.099
PR number triggered by event falling-edge
Address: 05C6H
05C7H
Default: 0x0000
Control mode: PR
Unit: -
Setting range: 0x0000 - 0xDDDD
Format: HEX
Data size: 16-bit
Settings:
UZ YX
The action when PR is EV1 falling-edge
X triggered
The action when PR is EV2 falling-edge
Y triggered
X: the action when EV1 is off
0: no action
1 - D: execute PR# 51 - 63
Y: the action when EV2 is off
0: no action
1 - D: execute PR# 51 - 63
Z: the action when EV3 is off
0: no action
1 - D: execute PR# 51 - 63
U: the action when EV4 is off
0: no action
1 - D: execute PR# 51 - 63
Z
The action when PR is EV3 falling-edge
triggered
The action when PR is EV4 falling-edge
U
triggered
8-202