Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P5.080
E-Cam: maximum correction rate for synchronous
Capture axis
Default: 10
Control mode: PR
Unit: %
Setting range: 0 to 90
Format: DEC
Data size: 16-bit
Address: 05A0H
05A1H
Settings:
This parameter limits the correction rate (%) of the synchronous Capture axis.
Correction rate = Pulse number output by the synchronous axis / Pulse number input by the
synchronous axis.
(100 - P5.080)% < Correction rate < (100 + P5.080)%
The bigger the correction rate, the faster the synchronous error falls to 0. However, the speed change is
more drastic. The smaller the correction rate, the slower the synchronous error becomes 0. However,
the speed change is smoother. In the rotary shear application, after the synchronous error of P5.079 is
adjusted, the bigger the parameter value is, the faster the cutting position is corrected. However, the
speed will not be synchronized.
P5.081
E-Cam: start address for data array
Address: 05A2H
05A3H
Default: 100
Control mode: PR
Unit: -
Setting range: 0 to (800 minus value set by P5.082)
Format: DEC
Data size: 16-bit
Settings:
Specifies the address of the data array to save the first data in the E-Cam curve table. This parameter
can be set at any time but will be effective only when the E-CAM system status changes from pre-
engaged to engaged.
P5.082
E-Cam: segment number (N)
Default: 5
Unit: -
Format: DEC
Control mode: PR
Setting range: 5 to 720
Data size: 16-bit
Address: 05A4H
05A5H
Settings:
Indicates that the E-Cam curve is divided into N segments, and the table includes N+1 data. This
parameter is only writable when E-Cam stops (P5.088.X [Bit 0] = 0). Its range must be smaller than or
equal to the value of P5.010 minus P5.081, and the value of P5.082 x P5.084 must be smaller than or
equal to 2147483647.