P5.074
Target speed setting #14
Address: 0594H
0595H
Operation
interface:
Panel
/
software
Default:
2500.0 (rotary)*
2500 (linear)*
Unit:
1
1
rpm (rotary)*
μm/s (linear)*
Setting
range:
0.0 to 7500.0 (rotary)*
0 to 15999999 (linear)*
Communication
Control mode: PR
25000
0.1 rpm (rotary)*
1 μm/s (linear)*
0 to 75000 (rotary)*
0 to 15999999 (linear)*
Data size: 32-bit
Format: DEC
-
-
Example:
1.0
1 =
=
1
1 rpm (rotary)*
μm/s (linear)*
10 = 1 rpm (rotary)*
1 = 1 μm/s (linear)*
-
-
Settings:
Target speed #14 of PR mode.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
P5.075
Target speed setting #15
Address: 0596H
0597H
Operation
interface:
Panel
/
software
Default:
3000.0 (rotary)*
3000 (linear)*
Unit:
1
1
rpm (rotary)*
μm/s (linear)*
Setting
range:
0.0 to 7500.0 (rotary)*
0 to 15999999 (linear)*
Communication
Control mode: PR
30000
0.1 rpm (rotary)*
1 μm/s (linear)*
0 to 75000 (rotary)*
0 to 15999999 (linear)*
Data size: 32-bit
Format: DEC
-
-
Example:
1.0
1 =
=
1
1 rpm (rotary)*
μm/s (linear)*
10 = 1 rpm (rotary)*
1 = 1 μm/s (linear)*
-
-
Settings:
Target speed #15 of PR mode.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
P5.076
Capture: reset position after first data captured
Address: 0598H
0599H
Default: 0
Control mode: All
Unit: Pulse unit of capture source
Setting range: -1073741824 to +1073741823
Format: DEC
Data size: 32-bit
Settings:
If the position reset function is enabled (P5.039.X [Bit 1] = 1), after the first position data is captured, the
servo resets the position of the first point, and the position of the reset point is defined by this parameter.
8-184
Send Quote Requests to info@automatedpt.com