Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
P5.049
Delay time #9 after position reached
Address: 0562H
0563H
Default: 2500
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #9 in PR mode.
8
P5.050
Delay time #10 after position reached
Address: 0564H
0565H
Default: 3000
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #10 in PR mode.
P5.051
Delay time #11 after position reached
Address: 0566H
0567H
Default: 3500
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #11 in PR mode.
P5.052
Delay time #12 after position reached
Address: 0568H
0569H
Default: 4000
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #12 in PR mode.
P5.053
Delay time #13 after position reached
Address: 056AH
056BH
Default: 4500
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #13 in PR mode.