Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P5.044
Delay time #4 after position reached
Address: 0558H
0559H
Default: 500
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #4 in PR mode.
P5.045
Delay time #5 after position reached
Address: 055AH
055BH
Default: 800
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #5 in PR mode.
P5.046
Delay time #6 after position reached
Address: 055CH
055DH
Default: 1000
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #6 in PR mode.
P5.047
Delay time #7 after position reached
Address: 055EH
055FH
Default: 1500
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #7 in PR mode.
P5.048
Delay time #8 after position reached
Address: 0560H
0561H
Default: 2000
Control mode: PR
Unit: ms
Setting range: 0 to 32767
Format: DEC
Data size: 16-bit
Settings:
Delay time #8 in PR mode.