Parameters
P5.034
Acceleration / deceleration time #14
Address: 0544H
0545H
Default: 50
Unit:
ms (P2.068.U = 0)
10 ms (P2.068.U =
1)
Format: DEC
Control mode: PR
Setting range: 1 to 1500
Data size: 16-bit
Settings:
The deceleration time setting for auto-protection. The default value is small for faster deceleration.
8
P5.035
Acceleration / deceleration time #15
Address: 0546H
0547H
Default: 30
Unit:
ms (P2.068.U = 0)
10 ms (P2.068.U =
1)
Format: DEC
Control mode: PR
Setting range: 1 to 1200
Data size: 16-bit
Settings:
The deceleration time for auto-protection. The default value is small for faster deceleration.
P5.036
Capture: start address of data array
Address: 0548H
0549H
Default: 0
Control mode: All
Unit: -
Setting range: 0 to (value set by P5.010 minus 1)
Format: DEC
Data size: 16-bit
Settings:
Specifies the address of the data array to save the first data to be captured. This parameter is only
writable when Capture stops (refer to P5.039).
P5.037Capture: axis position
Default: 0
Unit: Pulse unit of capture source
Format: DEC
Address: 054AH
054BH
Control mode: All
Setting range: -2147483648 to +2147483647
Data size: 32-bit
Settings:
Displays the axis position of the Capture pulse source. Note that this parameter is only writable when
Capture stops (refer to P5.039). If the pulse source of Capture is the main encoder, this parameter is
write-protected and the axis position is the feedback position of the motor (monitoring variable 00h).