ASDA-A3
8
P5.013Data array: window #2 for reading and writing
Address: 051AH
051BH
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Window #2: when read with the panel or read and written through communication, the value set by
P5.011 adds 1, but this parameter is not writable with the panel.
Refer to Section 7.2.1 Data array for detailed instructions.
P5.014
Reserved
P5.015PATH 1 - PATH 2 volatile setting
Address: 051EH
051FH
Default: 0x0000
Control mode: PR
Unit: -
Setting range: 0x0000 - 0x0011
Format: HEX
Data size: 16-bit
Settings:
This parameter allows you to write data to the target continuously through communication.
UZ YX
X PATH 1 volatile setting
Y PATH 2 volatile setting
X: PATH 1 volatile setting
0: non-volatile
1: volatile
Y: PATH 2 volatile setting
0: non-volatile
1: volatile
Z Reserved
U Reserved
8-166