Parameters
P5.009
Negative software limit
Default: -2147483648
Unit: PUU
Format: DEC
Address: 0512H
0513H
Control mode: PR
Setting range: -2147483648 to +2147483647
Data size: 32-bit
Settings:
In PR mode, if the motor moves in the negative direction and its feedback position exceeds the value of
P5.009, AL285 occurs.
8
P5.010Data array: data size
Default: -
Unit: -
Format: DEC
Address: 0514H
0515H
Control mode: All
Setting range: Read-only
Data size: 16-bit
Settings:
The total data size is N x 32 bits, where N indicates the number of data sets returned to the data array.
P5.011Data array: address for reading and writing
Address: 0516H
0517H
Default: 0
Control mode: All
Unit: -
Setting range: 0 to (value set by P5.010 minus 1)
Format: DEC
Data size: 16-bit
Settings:
Specify the address to read or write the data array. Refer to Chapter 7 for detailed instructions.
P5.012Data array: window #1 for reading and writing
Address: 0518H
0519H
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Window #1: when read with the panel, the value set by P5.011 does not add 1, but when read or written
by other methods, it adds 1.
Refer to Section 7.2.1 Data array for detailed instructions.