Parameters
P4.018
Current detector (W2 phase) - hardware offset calibration
Address: 0424H
0425H
Default: Factory setting
Control mode: All
Unit: -
Setting range: 13926 to 18842
Format: DEC
Data size: 16-bit
Settings:
Manually calibrate the hardware offset. The function must be enabled by setting P2.008. Do not change
the auxiliary calibration as this parameter cannot be reset.
8
P4.019
IGBT NTC calibration level (cannot reset)
Default: Factory setting
Unit: -
Format: DEC
Control mode: All
Setting range: 1 to 4
Data size: 16-bit
Address: 0426H
0427H
Settings:
Cool down the drive to 25°C (77°F) before calibration. The function must be enabled by setting P2.008.
P4.020
Analog monitor output (Ch1) - offset compensation value
Address: 0428H
0429H
Default: 0
Control mode: All
Unit: mV
Setting range: -800 to +800
Format: DEC
Data size: 16-bit
Settings:
Manually adjust the compensation value for the offset (cannot reset). The function must be enabled by
setting P2.008.
P4.021
Analog monitor output (Ch2) - offset compensation value
Address: 042AH
042BH
Default: 0
Control mode: All
Unit: mV
Setting range: -800 to +800
Format: DEC
Data size: 16-bit
Settings:
Manually adjust the compensation value for the offset (cannot reset). The function must be enabled by
setting P2.008.