Parameters
P4.010▲■ Hardware calibration options
Default: 0
Unit: -
Format: DEC
Control mode: All
Setting range: 0 to 14
Data size: 16-bit
Address: 0414H
0415H
Settings:
0: reserved
1: calibrate the offset of the analog speed input
hardware
2: calibrate the offset of the analog torque input
hardware
3: calibrate the offset of the current detector
(V phase)
4: calibrate the offset of the current detector (W
phase)
5: calibrate the offset of options 1 - 4
6 - 14: reserved
-
Note: the calibration function must be enabled by setting P2.008. When calibration, remove all external wirings for
torque input and make sure the servo is in the Servo Off state.
8
P4.011
Analog speed input 1 - hardware offset calibration
Address: 0416H
0417H
Default: Factory setting
Control mode: All
Unit: -
Setting range: 13926 to 18842
Format: DEC
Data size: 16-bit
Settings:
Manually calibrate the hardware offset. The function must be enabled by setting P2.008. Do not change
the auxiliary calibration as this parameter cannot be reset.
P4.012
Analog speed input 2 - hardware offset calibration
Address: 0418H
0419H
Default: Factory setting
Control mode: All
Unit: -
Setting range: 13926 to 18842
Format: DEC
Data size: 16-bit
Settings:
Manually calibrate the hardware offset. The function must be enabled by setting P2.008. Do not change
the auxiliary calibration as this parameter cannot be reset.
P4.013
Analog torque input 1 - hardware offset calibration
Address: 041AH
041BH
Default: Factory setting
Control mode: All
Unit: -
Setting range: 13926 to 18842
Format: DEC
Data size: 16-bit
Settings:
Manually calibrate the hardware offset. The function must be enabled by setting P2.008. Do not change
the auxiliary calibration as this parameter cannot be reset.