Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P3.022
EtherCAT PDO timeout setting
Default: 0xFF04
Unit: -
Format: HEX
Address: 032CH
032DH
Control mode: EtherCAT
Setting range: 0x0002 - 0xFF14
Data size: 16-bit
Settings:
When using the PDO to transmit data periodically, use this parameter to set the timeout setting. The
following two sets of digits specify the trigger conditions for AL180 and AL3E3 respectively to ensure
that the servo drive receives the PDO. When one of the alarm occurs, it means the allowable duration
for packet loss exceeds the set range.
UZ YX
Digit
Function
Range
UZ
AL180 trigger condition
0x00 (disabled) - 0xFF (default)
YX
AL3E3 trigger condition
0x02 to 0x14
YX: AL3E3 trigger condition (allowable cycle for elapsed time); applicable to CSP / CSV / CST
mode.
AL3E3 occurs when the servo drive does not receive the PDO within the set cycle.
When the communication cycle is 4 ms and you set this parameter to 0x02 (allow two cycles),
it means if the servo drive does not receive any PDO within 8 ms, AL3E3 occurs.
UZ: AL180 trigger condition (allowable duration for elapsed time); applicable to all operation
modes.
AL180 occurs when the servo drive does not receive the PDO within the set duration (unit: ms).
For example, when you set P3.022.UZ to 0x01, the duration is 1 ms; when you set P3.022.UZ to
0x02, the duration is 2 ms; and when you set P3.022.UZ to 0xFF, the duration is 255 ms.
P3.023 -
P3.038
Reserved
8-150